Changes

Security Camera Information

985 bytes added, 01:48, 4 December 2018
no edit summary
**'''Main Capture Resolution:''' 3072 x 1728
**'''Sub Capture Resolution:''' 640 x 350
 
=Hints, Tips, & Tricks=
*'''I can only see six (6) streams in a montage. The seventh get dropped.'''
**I saw this problem in ZoneMinder and Shinobi while using FireFox. It turns out that FireFox defaults to only allowing 6 streams per server.
**This can be fixed by going to ''about:config'' and changing the following settings
***browser.cache.check_doc_frequency '''3''' -> '''1''' (this causes FireFox to check for a new version of the page every time it is loaded)
***browser.cache.disk.enable '''True''' -> '''False''' (this disables FireFox's ability to cache page content to the hard drive)
***network.http.max-connections -> raise to 100
***network.http.max-persistent-connections-per-proxy -> raise to 100
***network.http.max-persistent-connections-per-server -> raise to 100 (this was originally 6 and probably the root cause of my problem)
=Links=
*https://reolink.com/wp-content/uploads/2017/01/Reolink-CGI-command-v1.61.pdf
*https://zoneminder.readthedocs.io/en/latest/faq.html#why-can-t-i-see-streamed-images-when-i-can-see-stills-in-the-zone-window-etc